US • 11
INDICATORS
1
0
A
B
C
D
E
2
3
4
5
6
Indication Description
0 Error mode, the charger suspends the charging / voltage maintenance.
See further description below.
1 Soft start.
2 Bulk charging, maximum voltage.
3 Absorption charging, voltage limited to chosen voltage.
4 Pulse maintenance charging
5 Supply, fixed output voltage, no counter voltage requirement.
6 Recond
A Charging without temperature compensation
B STANDBY
C Mode ” NORMAL” (14.4V)
D Mode ”SUPPLY” (13.6V)
E Mode ”RECOND” (15.7V, 3A 0.5–4h)
Error mode
The charger enters error mode before start in the following situations:
• The battery is connected with poles reversed to the charger's terminals.
• The terminals on the charger are short-circuited.
Error mode before start is reset by removing the error situation. The charger restarts in
the latest selected mode.
The charger enters steady error mode in the following situations:
• The charger’s analysis function has interrupted charging.
• The charger is overloaded in Supply mode.
• The charger has been in start mode longer than maximum time.
Steady error mode is acknowledged/reset by pressing the ”MODE” button. The charger
restarts in the latest selected mode.